TECLOMAN
1/1
Number of views:
1000

Marine Emergency Energy Storage System

Tecloman’s Marine Emergency Energy Storage System is a independent R&D backup power system for shipping, designed for providing crew basic daily needs when there is no shore power and do not start on diesel generator. The system is composed by charging cabin, battery cabin, battery module, discharging cabin, power cabin and background monitoring system.
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
1
Description

 

Marine Emergency Energy Storage System

Introduction

Tecloman’s Marine Emergency Energy Storage System is a independent R&D backup power system for shipping,
designed for providing crew basic daily needs when there is no shore power and do not start on diesel generator.
The system is composed by charging cabin, battery cabin, battery module, discharging cabin, power cabin and background monitoring system./span>

Product Feature

Flexible & Scalable:10/14cabin(optional), Scalable cabins by needs.

Easy Installation: Compact design makes it can be installed on wall to make full use of the cargo ship space.

Easy to replace: Weight<20kg, Portable easily.

Standard Design: Dimension, Software & Hardware interface are all of standard design. Modules’ numbers chosen by the electric consumption needs.Safe & Reliable: Using high-safety LFP and advanced BMS.

Parameters

 

Standard Module’s Parameters

Nominal Voltage(V) 25.6
Nominal Capacity(Ah) 75
Nominal energy(kWh) 1.92
Maximum Charging& Discharging Current(A) 37.5(0.5C)/75(1C)
Weight(kg) ≤20
Cycling(次) ≥4500(90%DOD)
Dimension(mm) 300×198×411
Battery Cabin’s Specification and Parameters
System’s Capacity(kVA) 15
Capacity(scalable)(kWh) 20(/40/60/80)
Accessible Branch Quantity of  Battery Cabin 1、2、3、4
Battery Cabin’s Dimension 1700mm×500mm×540mm
Battery Cabin’s Nominal Voltage(V) 256
Battery Cabin’s Nominal Current(A) 58.6
Battery Cabin’s Module Quantity 10
Battery’s Maximum Charging/Discharging Current(A) 37.5/75
Nominal Output Power(kW) 15
Battery Cabin’s Weight(KG) 220
Power Cabin’s Specification and Parameters
DC Side’s Parameters
VDC Range 200V~800V
DC Maximum Current 90A
DC Maximum Power 33kW
Accessible branch quantity of  battery 1/2/3/4
AC Off-grid Parameters
AC Off-grid Voltage 400V
AC Voltage Range ±5%
AC Off-grid Frequency 50Hz
THDu
< 1%(Linear Loads)
System Parameters
Maximum Efficiency 97.0%
Connection Type 3P4W + PE
Mounting Method Space Formula
Cooling Method Forced-air Cooling
Noise 60dB
Temperature Range -20℃~50℃
IP Level IP21
Altitude 4000m
Humidity Range 0 ~ 95%
Dimension(W*H*L) 600*600*1400mm
Weight 120kg
Communication Method
Display 7-inch Touch Screen
Host Computer Communication Method MODBUS TCP/IP / MODBUS RTU
Standard Communication Interfaces RS485/Ethnet/Wireless 4G

 